    ModTest Pro

    ModTest Pro

    MODBUS Testing Utility

    更新日志

    Added support for a number additional BLE devices. The app now scans for UART Service & TX/RX Characteristic UUIDs from BLE devices by the following manufacturers: DSD-TECH/Jinan Huamao, Laird, Nordic, Renesas, ST Microelectronics, Texas Instruments, & Silicon Labs. The exact UUIDs that are supported are detailed in the app User Guide.

    Added support for User Defined MODBUS Function Code 65. It can be used to request and display 32-bit floating point numbers as a single 32-bit register containing 4 bytes of data rather than having to use two consecutive 16-bit data registers.

    Updated the User Guide to document the new features and capabilities of the app.

    视频/截图

    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图

    应用描述

    MODTest Pro is a fast and simple utility for testing MODBUS devices over WiFi or Bluetooth. It supports a wide range of MODBUS functionality, including the ability to operate as a client or server (master or slave). It supports both TCP and UDP connections when using WiFi and it supports serial communication via many BLE modules equipped with Bluetooth 4 or higher that provide UART bridging capability.

    Tap the Setup button to enter the appropriate parameters for your device. Return to the main display to send your poll and view the data (when in client mode) or accept and respond to data requests from a master device (when in server mode).

    The Comm Setup view allows a number of addressing, timing, and communication mode parameters to be configured. Besides a comprehensive user guide, the app also has extensive built-in help. Tap on any yellow label or info button for a description of that parameter.

    The app supports MODBUS-TCP, -RTU, and -ASCII protocols, and they can all be transmitted via TCP, UDP, or Bluetooth. It also supports the GSI protocol which was developed in 1985 and was the first tank gauging protocol to use standard RS232/RS485 serial data communication. The app also features a User Data Mode that allows you to enter a complete poll string independent of any particular protocol. This allows transmission of special ASCII data polls or any MODBUS command that is not natively supported by the app.

    The following MODBUS function codes are supported:
    1 – Read Coils
    2 – Read Discrete Inputs
    3 – Read Holding Registers
    4 – Read Input Registers
    5 – Write Single Coil
    6 – Write Single Register
    7 – Read Exception Status
    15 – Write Multiple Coils
    16 – Write Multiple Registers
    17 – Report Server ID

    Addresses must be entered in standard MODBUS format (0-65535). If you are accustomed to specifying register addresses in "Modicon format", simply subtract 1 from the Modicon Address and delete the prefix number. For example, Modicon Holding Register 40101 is equivalent to MODBUS address 100.

    The app supports a wide range of data representations including:
    Unsigned Integer: 16 bit, 32 bit, and 64 bit
    Signed Integer: 16 bit, 32 bit, and 64 bit
    Floating Point: 32-bit, and 64-bit using IEEE-754 specifications
    Hex Data Strings: 16-bit, 32 bit, and 64-bit
    Bit and Byte Representations for Coils & Discrete Inputs

    The app also supports the following "reverse modes" of floating point data storage:
    Atomic 8-bit Little Endian
    Atomic 16-bit Little Endian
    PDP Endian
    Bit Reversal

    When you exit the Comm Setup page, WiFi connections will be established automatically; however, a manual scan must be initiated to find and select a BLE module within range in order to establish a Bluetooth connection. After a successful Wifi or BLE connection, simply tap the Start Poll button to send your poll command (when in client mode). Continuous polling is also supported. When in server mode, the app will wait for and respond to poll requests from a master device once a WiFi or BLE connection is made. The app scans for UART Service & TX/RX Characteristic UUIDs from BLE devices by a number of manufacturers. The UUIDs that are supported are detailed in the app User Guide.

    A communication status window will show the raw byte strings that are sent to and received from a remote device. Received data will also be shown in tabular form when in client mode and communication events will be shown when in server mode. The app also tracks a number of communication statistics.

    When using WiFi your device must be on the network as the device that you want to test. Be sure to use the Settings app to configure your network settings before using the app or you will surely get socket connection errors.

    The app contains no ads or in-app purchases and we will never nag you for reviews, although we do appreciate them. If you have any issues with the app, please send us a message before posting a negative review and give us a chance to address your concerns.
  • 版本: 1.05

    版本更新日期

    2022-12-05

    ModTest Pro

    ModTest Pro

    MODBUS Testing Utility

    更新日志

    Bug Fixes and UI Improvements - this version corrects a problem where some displays were the wrong size on iPod Touch 7th Gen and iPhone SE 1st Gen; also improved touches on some buttons and improved alignment of some displays.

    视频/截图

    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图

    应用描述

    MODTest Pro is a fast and simple utility for testing MODBUS devices over WiFi or Bluetooth. It supports a wide range of MODBUS functionality, including the ability to operate as a client or server (master or slave). It supports both TCP and UDP connections when using WiFi and it supports serial communication via HM-10 BLE modules.

    Tap the Setup button for the communication setup page to enter the appropriate parameters for your device. Return to the main display to send your poll and view the data (when in client mode) or accept and respond to data requests from a master device (when in server mode).

    The Comm Setup view allows a number of addressing, timing, and communication mode parameters to be configured. Besides a comprehensive user guide, the app also has extensive built-in help. Tap on any yellow label or info button for a description of that parameter.

    The app supports MODBUS-TCP, MODBUS-RTU, and MODBUS-ASCII protocols, and they can all be transmitted via TCP, UDP, or Bluetooth. It also supports the GSI protocol which was developed in 1985 and was the first tank gauging protocol to use standard RS232 and RS485 serial data communication media. The app also features a User Data Mode that allows you to enter a complete poll string independent of any particular protocol. This allows transmission of special ASCII data polls or any MODBUS command that is not natively supported by the app.

    The following MODBUS function codes are supported:
    1 – Read Coils
    2 – Read Discrete Inputs
    3 – Read Holding Registers
    4 – Read Input Registers
    5 – Write Single Coil
    6 – Write Single Register
    7 – Read Exception Status
    15 – Write Multiple Coils
    16 – Write Multiple Registers
    17 – Report Server ID

    Addresses must be entered in standard MODBUS format (0-65535). If you are accustomed to specifying register addresses in "Modicon format", simply subtract 1 from the Modicon Address and delete the prefix number. For example, Modicon Holding Register 40101 is equivalent to MODBUS address 100.

    The app supports a wide range of data representations including:
    Unsigned Integer: 16 bit, 32 bit, and 64 bit
    Signed Integer: 16 bit, 32 bit, and 64 bit
    Floating Point: 32-bit, and 64-bit using IEEE-754 specifications
    Hex Data Strings: 16-bit, 32 bit, and 64-bit
    Bit and Byte Representations for Coils & Discrete Inputs

    The app also supports the following "reverse modes" of floating point data storage:
    Atomic 8-bit Little Endian
    Atomic 16-bit Little Endian
    PDP Endian
    Bit Reversal

    When you exit the Comm Setup page, WiFi connections will be established automatically; however, a manual scan must be initiated to find and select a BLE module within range in order to establish a Bluetooth connection. After a successful Wifi or BLE connection, simply tap the Start Poll button to send your poll command (when in client mode). If you turn the Continuous Poll switch on, the Start Poll button will change to a Stop Poll button while the poll is in progress. When in server mode, the app will wait for and respond to poll requests from a master device once a WiFi or BLE connection is made.

    A communication status window will show the raw byte strings that are sent to and received from a remote device. Received data will also be shown in tabular form when in client mode and communication events will be shown when in server mode. The app also tracks a number of communication statistics.

    When using WiFi your device must be on the network as the device that you want to test. Be sure to use the Settings app to configure your network settings before using the app or you will surely get socket connection errors.

    The app contains no ads or in-app purchases and we will never nag you for reviews, although we do appreciate them. We appreciate your feedback and the app includes a convenient email form to send us comments or suggestions. If you have any issues with the app, please send us a message before posting a negative review and give us a chance to address your concerns.
  • 版本: 1.04

    版本更新日期

    2022-10-11

    ModTest Pro

    ModTest Pro

    MODBUS Testing Utility

    更新日志

    User Interface Improvements

    视频/截图

    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图

    应用描述

    MODTest Pro is a fast and simple utility for testing MODBUS devices over WiFi or Bluetooth. It supports a wide range of MODBUS functionality, including the ability to operate as a client or server (master or slave). It supports both TCP and UDP connections when using WiFi and it supports serial communication via HM-10 BLE modules.

    Tap the Setup button for the communication setup page to enter the appropriate parameters for your device. Return to the main display to send your poll and view the data (when in client mode) or accept and respond to data requests from a master device (when in server mode).

    The Comm Setup view allows a number of addressing, timing, and communication mode parameters to be configured. Besides a comprehensive user guide, the app also has extensive built-in help. Tap on any yellow label or info button for a description of that parameter.

    The app supports MODBUS-TCP, MODBUS-RTU, and MODBUS-ASCII protocols, and they can all be transmitted via TCP, UDP, or Bluetooth. It also supports the GSI protocol which was developed in 1985 and was the first tank gauging protocol to use standard RS232 and RS485 serial data communication media. The app also features a User Data Mode that allows you to enter a complete poll string independent of any particular protocol. This allows transmission of special ASCII data polls or any MODBUS command that is not natively supported by the app.

    The following MODBUS function codes are supported:
    1 – Read Coils
    2 – Read Discrete Inputs
    3 – Read Holding Registers
    4 – Read Input Registers
    5 – Write Single Coil
    6 – Write Single Register
    7 – Read Exception Status
    15 – Write Multiple Coils
    16 – Write Multiple Registers
    17 – Report Server ID

    Addresses must be entered in standard MODBUS format (0-65535). If you are accustomed to specifying register addresses in "Modicon format", simply subtract 1 from the Modicon Address and delete the prefix number. For example, Modicon Holding Register 40101 is equivalent to MODBUS address 100.

    The app supports a wide range of data representations including:
    Unsigned Integer: 16 bit, 32 bit, and 64 bit
    Signed Integer: 16 bit, 32 bit, and 64 bit
    Floating Point: 32-bit, and 64-bit using IEEE-754 specifications
    Hex Data Strings: 16-bit, 32 bit, and 64-bit
    Bit and Byte Representations for Coils & Discrete Inputs

    The app also supports the following "reverse modes" of floating point data storage:
    Atomic 8-bit Little Endian
    Atomic 16-bit Little Endian
    PDP Endian
    Bit Reversal

    When you exit the Comm Setup page, WiFi connections will be established automatically; however, a manual scan must be initiated to find and select a BLE module within range in order to establish a Bluetooth connection. After a successful Wifi or BLE connection, simply tap the Start Poll button to send your poll command (when in client mode). If you turn the Continuous Poll switch on, the Start Poll button will change to a Stop Poll button while the poll is in progress. When in server mode, the app will wait for and respond to poll requests from a master device once a WiFi or BLE connection is made.

    A communication status window will show the raw byte strings that are sent to and received from a remote device. Received data will also be shown in tabular form when in client mode and communication events will be shown when in server mode. The app also tracks a number of communication statistics.

    When using WiFi your device must be on the network as the device that you want to test. Be sure to use the Settings app to configure your network settings before using the app or you will surely get socket connection errors.

    The app contains no ads or in-app purchases and we will never nag you for reviews, although we do appreciate them. We appreciate your feedback and the app includes a convenient email form to send us comments or suggestions. If you have any issues with the app, please send us a message before posting a negative review and give us a chance to address your concerns.
  • 版本: 1.03

    版本更新日期

    2021-07-03

    ModTest Pro

    ModTest Pro

    MODBUS Testing Utility

    更新日志

    • Added support for MODBUS FC7 and FC17 in both client and server mode
    • Fixed some data display bugs
    • Corrected some typos
    • Updated the User Manual to reflect the new features

    视频/截图

    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图

    应用描述

    MODTest Pro is a fast and simple utility for testing MODBUS devices over WiFi or Bluetooth. It supports a wide range of MODBUS functionality, including the ability to operate as a client or server (master or slave). It supports both TCP and UDP connections when using WiFi and it supports serial communication via HM-10 BLE modules.

    Tap the Setup button for the communication setup page to enter the appropriate parameters for your device. Return to the main display to send your poll and view the data (when in client mode) or accept and respond to data requests from a master device (when in server mode).

    The Comm Setup view allows a number of addressing, timing, and communication mode parameters to be configured. Besides a comprehensive user guide, the app also has extensive built-in help. Tap on any yellow label or info button for a description of that parameter.

    The app supports MODBUS-TCP, MODBUS-RTU, and MODBUS-ASCII protocols, and they can all be transmitted via TCP, UDP, or Bluetooth. It also supports the GSI protocol which was developed in 1985 and was the first tank gauging protocol to use standard RS232 and RS485 serial data communication media. The app also features a User Data Mode that allows you to enter a complete poll string independent of any particular protocol. This allows transmission of special ASCII data polls or any MODBUS command that is not natively supported by the app.

    The following MODBUS function codes are supported:
    1 – Read Coils
    2 – Read Discrete Inputs
    3 – Read Holding Registers
    4 – Read Input Registers
    5 – Write Single Coil
    6 – Write Single Register
    7 – Read Exception Status
    15 – Write Multiple Coils
    16 – Write Multiple Registers
    17 – Report Server ID

    Addresses must be entered in standard MODBUS format (0-65535). If you are accustomed to specifying register addresses in "Modicon format", simply subtract 1 from the Modicon Address and delete the prefix number. For example, Modicon Holding Register 40101 is equivalent to MODBUS address 100.

    The app supports a wide range of data representations including:
    Unsigned Integer: 16 bit, 32 bit, and 64 bit
    Signed Integer: 16 bit, 32 bit, and 64 bit
    Floating Point: 32-bit, and 64-bit using IEEE-754 specifications
    Hex Data Strings: 16-bit, 32 bit, and 64-bit
    Bit and Byte Representations for Coils & Discrete Inputs

    The app also supports the following "reverse modes" of floating point data storage:
    Atomic 8-bit Little Endian
    Atomic 16-bit Little Endian
    PDP Endian
    Bit Reversal

    When you exit the Comm Setup page, WiFi connections will be established automatically; however, a manual scan must be initiated to find and select a BLE module within range in order to establish a Bluetooth connection. After a successful Wifi or BLE connection, simply tap the Start Poll button to send your poll command (when in client mode). If you turn the Continuous Poll switch on, the Start Poll button will change to a Stop Poll button while the poll is in progress. When in server mode, the app will wait for and respond to poll requests from a master device once a WiFi or BLE connection is made.

    A communication status window will show the raw byte strings that are sent to and received from a remote device. Received data will also be shown in tabular form when in client mode and communication events will be shown when in server mode. The app also tracks a number of communication statistics.

    When using WiFi your device must be on the network as the device that you want to test. Be sure to use the Settings app to configure your network settings before using the app or you will surely get socket connection errors.

    The app contains no ads or in-app purchases and we will never nag you for reviews, although we do appreciate them. We appreciate your feedback and the app includes a convenient email form to send us comments or suggestions. If you have any issues with the app, please send us a message before posting a negative review and give us a chance to address your concerns.
  • 版本: 1.02

    版本更新日期

    2021-06-27

    ModTest Pro

    ModTest Pro

    MODBUS Testing Utility

    更新日志

    • Fixed a packet timeout bug when using BLE communication
    • Some UI improvements
    • Enabled landscape view of PDF documents
    • Corrected several typos
    • Added more options to the Documents view

    视频/截图

    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图
    ModTest Pro App 截图

    应用描述

    MODBUS Test Pro is a fast and simple utility for testing MODBUS devices over WiFi or Bluetooth. It supports a wide range of MODBUS functionality, including the ability to operate as a client or server (master or slave). It supports both TCP and UDP connections when using WiFi and it supports serial communication via HM-10 Bluetooth Low Energy (BLE) modules.

    Simply tap the Setup button for the communication setup page to enter the communication parameters for your device. Return to the main display view to send your poll and view the data (when in client mode) or accept and respond to data requests from a master device (when in server mode).

    The Comm Setup view allows a number of addressing, timing, and communication mode parameters to be configured. Besides a comprehensive user guide, the app also has extensive built-in help. Tap on any yellow label or info button for a description of that parameter.

    The app supports MODBUS-TCP, MODBUS-RTU, and MODBUS-ASCII protocols, and they can all be transmitted via TCP, UDP, or Bluetooth. It also supports the GSI protocol which was developed in 1985 and was the first tank gauging protocol to use standard RS232 and RS485 serial data communication media. The app also features a User Data Mode that allows you to enter a complete poll string independent of any particular protocol. This allows transmission of special ASCII data polls or any MODBUS command that is not natively supported by the app.

    The following MODBUS function codes are supported:
    1 – Read Coils
    2 – Read Discrete Inputs
    3 – Read Holding Registers
    4 – Read Input Registers
    5 – Write Single Coil
    6 – Write Single Register
    15 – Write Multiple Coils
    16 – Write Multiple Registers

    Addresses must be entered in standard MODBUS format (0-65535). If you are accustomed to specifying register addresses in "Modicon format", simply subtract 1 from the Modicon Address and delete the prefix number. For example, Modicon Holding Register 40101 is equivalent to MODBUS address 100.

    The app supports a wide range of data representations including:
    Unsigned Integer: 16 bit, 32 bit, and 64 bit
    Signed Integer: 16 bit, 32 bit, and 64 bit
    Floating Point: 32-bit, and 64-bit using IEEE-754 specifications
    Hex Data Strings: 16-bit, 32 bit, and 64-bit
    Bit and Byte Representations for Coils & Discrete Inputs

    The app also supports the following "reverse modes" of floating point data storage:
    Atomic 8-bit Little Endian
    Atomic 16-bit Little Endian
    PDP Endian
    Bit Reversal

    When you exit the Comm Setup page, WiFi connections will be established automatically; however, a manual scan must be initiated to find and select a BLE module within range in order to establish a Bluetooth connection. After a successful Wifi or BLE connection, simply tap the Start Poll button to send your poll command (when in client mode). If you turn the Continuous Poll switch on, the Start Poll button will change to a Stop Poll button while the poll is in progress. When in server mode, the app will wait for and respond to poll requests from a master device once a WiFi or BLE connection is made.

    A communication status window will show the raw byte strings that are sent to and received from a remote device. Received data will also be shown in tabular form when in client mode and communication events will be shown when in server mode. The app also tracks a number of communication statistics.

    When using WiFi your device must be on the network as the device that you want to test. Be sure to use the Settings app to configure your network settings before using the app or you will surely get socket connection errors.

    The app contains no ads or in-app purchases and we will never nag you for reviews, although we do appreciate them. We appreciate your feedback and the app includes a convenient email form to send us comments or suggestions. If you have any issues with the app, please send us a message before posting a negative review and give us a chance to address your concerns.